Emergency Showers & Eye Wash Stations
Inspection and servicing for uninterrupted emergency response.
Applicable Standards

Scope of work
- Functional and flow testing of emergency showers and eyewash stations
- Deep cleaning of shower and eyewash heads
- Inspection of valves, pull rods, piping, and water pressure
- Compliance certificate (soft & hard copy)
- Equipment-wise tagging & traceability, photo evidence (with permission), corrective action summary
Deliverables
- On-Site : At your plant or shutdown location
- Off-Site : Udyogi Service Centres – Ranihati & Ahmedabad
SCBA (Self-Contained Breathing Apparatus) Servicing
Self-Contained Breathing Apparatus (SCBA) is essential for protecting workers in toxic, smoke-filled, oxygen-deficient, and other hazardous environments. As life-saving equipment, SCBA systems must be regularly inspected and maintained to ensure reliable performance during emergencies.
SCBA Refilling & Inspection
Regular refilling, inspection, and maintenance ensure the equipment remains reliable, compliant, and ready for emergency use. Routine checks help identify wear, damage, or performance issues before they compromise worker safety. Assuring the SCBA functions effectively when needed .


Cylinder Hydrostatic Testing
Hydrostatic testing is a mandatory safety inspection used to verify the structural integrity of SCBA cylinders. The test helps detect leaks, cracks, deformation, or weaknesses that could affect cylinder performance under pressure. Regular hydrostatic testing ensures that cylinders remain safe for continued use and compliant with applicable safety standards and regulations.
Gas Detector Calibration & Maintenance
Regular calibration is essential in order to maintain the reliable performance and accuracy of most gas detectors. During calibration, thorough testing is also carried out to ensure that the gas detector remains sufficiently sensitive and responsive to the exposure of gas required. In addition to accuracy, calibration also helps extend the lifespan of gas detectors. Over time, sensors may drift or become less responsive due to environmental factors or regular use. Regular calibration corrects these issues and ensures the device provides timely warnings.

Applicable Standards
Fit Testing
Proper fit testing ensures respiratory protective equipment provides an effective seal and the intended level of protection. Udyogi's fit testing services help organizations verify mask fit, improve worker safety, and support regulatory compliance.
We offer inspection and services related to:
- Disposable Respirators
- Half Face Respirators
- Full Face Respirators